Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHICH INSTRUMENT USED TO CALIBRATE CONTROL VALVE?

Answer Posted / janardhan reddy

we can calibrate the control valve by using the dead weight
tester and transmitter and pid controller,

Is This Answer Correct ?    7 Yes 24 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I installed the smartplant instrument v8, but can not be opened, that always said: "INTools 2007 hardlock no found". So Could you help me how to do for that?

2049


What is mean by analytical instrumentation?

1811


what is the procedure of O2 sensor(ABB) calibration?

2180


I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.

1785


how to calibrate steam control valve in steam turbine

3324


We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1650


what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????

5014


How to calibrate displacer type level transmitter (chemtrol make )for level measurement in hotwell , LP & HP heater ?

5900


sir,would you please send me the Hindustan petroleum corporation limited papers(HPCL).my e-mail ID is ujjwal_sharma1983@yahoo.com

2320


line up procedure for dp type flow transmitter?

1897


Make Heater Process Logic.

2096


What is the difference between ff transmitter and non ff transmitter

2435


How digital input and digital output 's are working in dcs

2541


Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?

1881


what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?

2476