Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Waht will happened if reactive power increase in the line?
waht about active power increase too?

Answer Posted / iamdon

Reactive power flows from higher voltage to lower
voltage.Flow of increased reactive power in line
causes power factor to reduce.For fixed value of
sending end voltage, receiving end voltage drops.
Active power flows from side which has leading
voltage angle to lagging end.
Increased Active power flow causes more line losses.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the advantages of having in-built acvvvf (without seperate inverter in the control panel)in the drive system of elevators?

3372


how generator load test is conducted?what are the steps?

1591


Can anyone please provide me details of MCCB/Contactor/SFU rating calculations for a motor feeder..for example 50 kw.. not from type-2 cordination chart. i want manual calculations..

2579


What are the weight of 800KV DA,DB and DC type tower ?

3139


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2146


hi everybody how to design string combiner box (scb) internal parameters like bus bar and spd (surge protection device and fuse which place to set that,and also bus bar one particular cross sectional how much heat generated and how much power loss tell me Clearly and briefly

1981


What are the various types of rotor used in the alternators?

1066


How to design pavement quality concrete by using C.R.C.P Method

1739


What is the approximate value of stacking factor?

1155


what is two point starter?

2106


How to derive detailed design of Suitable bus Bar for 100A for 6.6KV?

1803


What is an ac motor?

1267


What is non-minimum phase transfer function?

1295


IN dc capacitive reactance is??

1386


If a high resistance fault occurs,then what are the changes will happen in the system?

1447