1.DIFFERENCE BETWEEN NOMINAL MIX AND DESIGN MIX?
2.WHAT IS MEANT BY STRUCTURAL DESIGN?
3.IN STAAD WHY WE RELEASE MOMENT TO A MEMBER?
4.ON WHAT BASIS PARTIAL FACTOR OF SAFETY ARE DECIDE?FROM
THE LOAD COMBINATION?
5.WHY WE PROVIDE EXTRA BAR & DEVELOPEMENT LENGTH AT TOP?
6.FULL FORM OF SPT & SMB?
7.WHAT IS MEANT BY ITP IN A CONSTRUCTION PROJECT?
8.WHAT IS LEAST COUNT OF THEODOLITE SURVEY?
9.WHAT ARE THE CAUSES OF FAILURE OF FOUNDATIONS AND
REMEDIAL MEASURES?
10.WHAT ARE THE VALUES OF COMPRESSIVE STRENGTH?
11.STEEL CALCULATION FOR FOOTING,BEAM & SLAB?
12.WHAT IS MEANT BY GANTRY GIRDER?
13.IN SITE HOW WE CAN IDENTIFY THE ONE WAY, TWO WAY SLAB?
14.DIFFERENCE BETWEEN ANCHORAGE LENGTH & DEVELOPEMENT
LENGTH?
15.BEARING CAPACITY OF STEEL SHUTTERING?LOAD CARRYING FOR
SHUTTERING?
Answer Posted / s c jayakumar
1.Nominal mix is standard mix formulated by BIS comittee
for construction use where as design mix is that,With the
optimum cement content and proprely graded/blended mix
constituents used to form rigid congolomarate for better
durability.Using of optimum cement content is to get
economic construction without compromising of durability of
structure.
| Is This Answer Correct ? | 9 Yes | 1 No |
Post New Answer View All Answers
what radial pressure, the NP2 class rcc pipe can sustain?
difference between trapezoidal and pedestal footing and how the load acts on that
how to caluclate sienerge qty in construction in ap
manhole chamber having height of 2300 mm and thickness of brickwork is 230 mm and dia of opening covering is 560 mm and bottom length vertical is 1500 mm (1:4) brick masonry and plaster 12 mm on both sides..how to estimate the no bricks used with mortar cement bags and sand for total chamber including plaster.
Explain how you can turn off the display for dimension in CAD?
Please tell me Detail cost of providing& laying nominal mix design 1:2.5:5,40mm nominal size.curing complete e/c cost of form work in foundation and plinth i/c carriage.
it is a corrected question." make a list of engineering property(properties) of soil.
How to find coloumn vertical cut length floor to floor & lap + bend or anything plz clearfiy
What is the ratio of grades m5, m7.5, m10, m15, m20, m25, m30, m35, m40?
plumbing CPVC fitting FTE Brass full form
What is the basic difference between OPC
step by step procedure to find out the percentage of steel in coloum,beam,slab,footing in detailed
How do we calculate the power of centrifugal pump?
Can anyone suggest how to determine scheduling of reinforcement of floor beams from Staad model,other than clicking each beam respectively 7 noting down the values ?
What is difference between code and standard and specification?