Answer Posted / sanjay jangra
secondary full load current
if secondary is star/delta connection
X: 118.09A Y: 118.09A Z: 118.09A
Is This Answer Correct ? | 2 Yes | 2 No |
Post New Answer View All Answers
I would like to know that the fault curretn at base load and at 10% generation will be same? Fault level of BUS remain same with different generation?
hi every body i am master student in control engineering and my project is slip control in trains i assumed a Dc motore as traction motor but i don't have characteristics of this kind of motor that is used in train. i want from every body if he or she has the characteristics or information about Dc motor that is used in train give me those information or technical characteristics .
what reason of line current and phase current in star connection and line current and phase current not equal in delta connection?
which protection used in power plant?
what is meant by flywheel and its role in retardation test
I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
Is it true online ups having bypass mode if it is true then why we called ups because it is interrupting power when goes in bypass mode
how to protect motor in dol starter having capacity of 30 hp.40 hp?
my name is venkat .i have good percentage in my academics(ssc 86, intermediate 83 b.tech 73) my question 1..after completion of my ssc i joined in bpc but i didnt got rank in emcet so i completed MPC in one year compartmentally ..so here what am expect question from this background?
what is the relative size of single and three phase?
Brief working principle of stabilizer,application & safety precautions
Currently what is the highest capacity (MVA) of SPPg generator available in the market?
i need list of swg(standard wire guage) or area of conductor v/s current carrying capacity of conductor copper & alluminium...
for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?