what is the difference between DELTA-V & FOUNDATION FIELD
BUS
Answer Posted / vaibhav v t
Delta v is the DCS offered by Emerson.
Foundation feildbus is protocol for dgital signal
transmission.FF is next level of digital communication
after HART.
| Is This Answer Correct ? | 28 Yes | 1 No |
Post New Answer View All Answers
Can please tell mi about SIOS, PRM, SERVER, and what is the diference between PIN LAN, PCS LAN,APC Server, and please send the Doc if possible for referance,mail id patil_amit17@yahoo.com
How to calibration a control valve?
What are the interlocks we have to check during the start up of LP/HP compressor?
sir i m preparing for BARC but i am not getting any papers to prepare for this exam so please send me some sample papers to my i.d for the preparation of barc.
How does temperature bath work? How does coil gets heated only by applying some current?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
Coal mill Instruments Equipments for cement plant And process diagram ?
How is work 5/2 sov?
draw shematic diagram of c/v positioner(smart type)?
how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?
typical loop drawing of a simple feedback control comprising of one transmitter and one control
components of control circuit belongs to control valve
model question paper of instrumentation for Jindal GET 2010.plz reply sudhanshukumar08@yahoo.com
I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.
how to calibrate electro pneumatic positioner 8013 mil controls ltd ?gsr