Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the List of Equipments, Instruments, Components
required in Transmission of electricity from 1 substation
to other substation(The equipments required in substation
too)?

What are the differnt IS standrds used for above equipments
in Industry?

Answer Posted / kumaresan r

LIST EQUIPMENT IN SUBSTATION ARE CT,PT,TRANSFORMER,LA,INSULATOR,ISOLATOR (SINGLE ,DOUBLE)

FOR TRANSMISSION SUPPLY WE NEED ALL THIS EQUIPMENT

PLEASE REFER INDIAN STANDARD RULE ,OR BIS RULE

Is This Answer Correct ?    9 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is ignition module of a CAT Gas Genset G-3508 Engine, Alternator SR4B Series. HOw its checked for correct functioning.Is it repiarable or replacable?

2194


On what cycle does thermal power plant operate?

1169


What size cable (based on voltage drop) is required to supply a 40 A three phase boiler if the wiring system is 75V single insulated cables installed in non-metallic rigid conduit 56m from the main switchboard? Voltage drop in the consumer's mains is 8V.

1982


bsnl tta exam question

1883


is it possible to turn on the single phase star delta on delay timer using 24 v dc ?

2055


How to calculate earth wire load by formula

2590


what is a bus post insulator? explain its application in a substation.

12610


what is the need to express current and voltage in rms value? rms value is also called as effective value,what is effective value?

1975


what is the function of bearing in dc mchine" and where it is placed

2598


What is meant by system?

1074


Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?

1666


Percentage losses in power generation?

2997


how is positive, negative, zero sequence is happen.. how is effect on 3 phase system

1808


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2154


please send me RRB electrical engineer previous year questions for Sr. Section Engineer

1960