What is the List of Equipments, Instruments, Components
required in Transmission of electricity from 1 substation
to other substation(The equipments required in substation
too)?
What are the differnt IS standrds used for above equipments
in Industry?
Answer Posted / kumaresan r
LIST EQUIPMENT IN SUBSTATION ARE CT,PT,TRANSFORMER,LA,INSULATOR,ISOLATOR (SINGLE ,DOUBLE)
FOR TRANSMISSION SUPPLY WE NEED ALL THIS EQUIPMENT
PLEASE REFER INDIAN STANDARD RULE ,OR BIS RULE
| Is This Answer Correct ? | 9 Yes | 1 No |
Post New Answer View All Answers
What is ignition module of a CAT Gas Genset G-3508 Engine, Alternator SR4B Series. HOw its checked for correct functioning.Is it repiarable or replacable?
On what cycle does thermal power plant operate?
What size cable (based on voltage drop) is required to supply a 40 A three phase boiler if the wiring system is 75V single insulated cables installed in non-metallic rigid conduit 56m from the main switchboard? Voltage drop in the consumer's mains is 8V.
bsnl tta exam question
is it possible to turn on the single phase star delta on delay timer using 24 v dc ?
How to calculate earth wire load by formula
what is a bus post insulator? explain its application in a substation.
what is the need to express current and voltage in rms value? rms value is also called as effective value,what is effective value?
what is the function of bearing in dc mchine" and where it is placed
What is meant by system?
Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?
Percentage losses in power generation?
how is positive, negative, zero sequence is happen.. how is effect on 3 phase system
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
please send me RRB electrical engineer previous year questions for Sr. Section Engineer