CAN ANYBODY PL TELL ME WAT FACTORS CAN CAUSE UNDERVOLTAGE
ON A BUS??? PL LIST ALL THE REASONS WITH SOME EXPLAINATION
Answer Posted / amit srivastava
yes there are so many problems will raised on bus bar
first of all it increase the current which will creates
losses in transmission line nd other thing it makes poor
power factor which make transmission conductor less
efficient
as for as bar is concern it will decrese the flux of the
generator so it will creats severe problem to the alternator
| Is This Answer Correct ? | 0 Yes | 2 No |
Post New Answer View All Answers
Dg pf .71 i am improve pf 0.80 what capacitor connected in dg how?
diameter of cable and core is doubled then the value of capacitance is
What is the operating principle of turbo-generator.
Why do we need interlocking in a HT metering or Ring main unit switchgear?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
how can i determine the gear ratio for a rack and pinion system if an electronic gate operated by an electric motor is to travel a distance of 5meters in 15 seconds.
A 7 storey building has a floor area of 35,000sq.ft on each storey. On the ground floor 11KV electrical sub-station is to be erected. A load of 3kw for every 400sq.ft (p.f is 0.8) is proposed for each floor. fire pump 7.5hp, water pump 5hp, lift 2 nos, each 10hp and 20shop load of each shop is 5kw. calculate a. load each floor b. total load of building c. L.T feeders for aech floor and from transformer to main. d. distribution diagram e. capacity of sub-station/capacitor bank f. line diagram
How To increase Knowledge Of boliler regarding To Only Electrical Field..
what is the profesional board for electrical engineer what is thepast and during construction for electrical engineering
What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?
What happen to generator if i have unbalanced load?
Why does the adjacent zone of protection overlap?
in basic 2 phase will short means tripping the power but spot welding 2 phase shorting but not tripping it will welded why.....(Q)
what is the effect of power factor of machines in starting current
what is the necessary of using inductance property in transmission lines even through resistance is used to opposes the high current flows in that?????