Answer Posted / mahavir jagdev
the choke along with the starter is used to give the high voltage start to the tube light which has heating filaments at both ends to ionize the gas inside. once the tube starts glowing then only 90 volts is required to keep it going, so the starter stops the current flow into the heating filaments and the choke uses it's impedence to absorb the extra voltage from 220 volts to keep the tube light voltage to 90 volts.
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
What is Primary And Secondary Injection Test of Relay and Other Electrical Devices. How IT is carried out.
How to calculate loses in transformer of 160 KVA ?
Why reactive power is needed in a power system? How is it being absorbed or delivered by alternators? For reactive power control we are changing excitation but reactive power absorbing or delivering related to stator. How these two are interlinked? i want a detailed explanation with necessary expressions and figures?
what are the available sizes of pin type terminal lugs in the market today?
A cotter joint is generally used to transmit
Explain about 3 phase motor fault current calculation with examples?
In DC generator, we use commutator, having no. of segments. Then how it is possible to get a half wave of voltage and current for half rotation of armature?
Is it possible to use a S1 duty class motor for crane application (S4)? If not, why?
hi pal, i am vengatesh from tamilnadu(chidambaram),i have called for the written test for the post of jr executive(ELECTRICAL) of AAI ,I dont know about the question paper pattern,so any kindly help me to face the examination,post me the model question papers and some tips to write my examination to (vengi.annadurai@gmail.com)
What is lifting power for 1 wb/m2 and 1 A magnet?
An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm
at meter room 50 hrc switch installed,but there are not get earthing proper,so what happen?and 11kv transformer out put going in to hrc main 400a three nog each? so earthing is require for all switch? (some customer made earthing at there home.)
how can see the ac indoor or out door ac which Tr
why electronic instruments is more favorable than electrical?
sir please send me techinical questions for junior engineer posting in bangalore railway i am diploma holder