WHICH INSTRUMENT USED TO CALIBRATE CONTROL VALVE?
Answer Posted / nawras
by force 4-20ma from vontrol valve and see what the responce
that meaning 4ma for 0
8ma for 25%
12ma for 50%
16ma for 75%
20ma for 100%
| Is This Answer Correct ? | 21 Yes | 6 No |
Post New Answer View All Answers
use of split range ? where it is used ? in which control loop it is used ?
sir, give me placement papers and interview quistion of birla group company of copper.
Explain about safety integrated level protection? . How it was differ from other protections ?
What are different types of control valves?
What is profibus?
what is intrinscily safe system and where we use?
Can Any body tell me about the Contact or Email id of any good Consultancy which help me to find a job in Instrumentation Field in India .I have Six years of Work Experience in the Same field.Please revert me back on shammi_gwalior@yahoo.com ?
how u calibrate pneumatic n motorized c/v?
What are the different types of thermistors used in industries? How to the operation of typical thermistor?
Why thermo wells are used? What materials are used in thermo wells?
How to Calibrate Coriolis Flow transmitter in field
in valve is constructed as per SME B 16.34, then which standard is used for fire testing of valve?.
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
please tell no. & add. of consultancy who recruit me in power plant as instrumen engg. present i m working in power plant as ass.t instrument engg. thanku mahesh 09226562826
How we can check the 2 wire proxy switch? & how it is connected to DI MODULE OF PLC?