Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why Power generation in India is at 50Hz while in America
its 60Hz so is there any advantage/Disadvantage of this ??

Answer Posted / thuranga

hey guys I found another answer for it......

if we consider the temperature parameters of the
America....then it is almost cool all through the
year,excepting 2 to 3 months maximum.

we all know that in conductors, heating the conductors will
lower its resistance,similarly,cooling also increases the
resistance.
so for preventing the losses, the driving current must be
high, but to maintain the power constant the voltage is
reduced to 110V. So to make the current high,frequency will
be high,and they found that losses were low on operation of
equipment at 60Hz than at 50Hz.

but when u take tropical places almost the whole operation
is with 50Hz.

but here arises another question that,equator passes through
America also,but even then they use 60Hz for their operation.?
My answer is, there will be no different power generations
with different ratings of voltage and frequencies,as all the
states are interconnected just similar to other countries to
meet the demand of power.
so for small number of states the whole country is not going
to change the operation of frequency.

Is This Answer Correct ?    25 Yes 22 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why co incidence factor considered in transformer sizing?

1921


1.dg on load alarm/stop alarm... 2.dg on load. piu alarm alarm kaise chek krte hai

2000


how can get electrical c licence.now i am working in spining mill , transformer capacity 2750KVA. SANCTION DEMAND 2250KVA. PLEASE ADVISE ME . MY CONTACT NO 09944226823

1839


how to store the thunder power?

4574


Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT

2630


1.what is difference between ATS & STS main use. 2.what is difference between ACB& VCB With symobles,and main partes, manimum range. 3.How many types of relays and main function.

6339


Is it acceptable of installing an earth pit in planters area where bare copper cable, earth rod and connection are susceptible to corrosion due to water?

2001


internally connection of photvoltic module

1979


what is meant by 3rd hormonics ?

2096


if a.c supply is given to the motor,, what happen?

2214


What do you mean by power transformer?

1144


How to calculate Air conditioning capacity for a telecom BTS shelter?

3553


while doing high voltage test on 11kv/433 distribution transformer why we only give 28 kv on hv side and 3kv on lv side for power transformers what is the value what factors it depends

2912


why electronic instruments is more favorable than electrical?

2018


how does a submersible pump work..?

1934