Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why stand-by earth fault relay and restricted earth fault
relays are connected between neutral and ground in
transformer?

Answer Posted / p.chandramouli

Because the neutral of the Transformers are connected to
ground. And the return currents as well as unbalance
currents flow in neutral in the process of balancing the 3
phase winding system of the Transformer.

Is This Answer Correct ?    1 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between a verilog task and verilog function?

1281


Can we use Ccapacitive voltage transformer directly for metering purpose?

1852


state working of halogen lamp?

1817


what is the difference between Central Battery System and UPS in applications and uses? and why UPS suitable for Computers and central battery for emergency lighting?

10295


What is the difference between a 3 winding and 2 winding Potential Transformer

2274


How to minimize the eddy current losses?

1174


Is it possible to use a S1 duty class motor for crane application (S4)? If not, why?

2439


1. Why is the speed of shunt motor practically constant? 2. Why dc series motor use to start with heavy loads? 3. advantages & disadvantages of separately excited generator over self excited generator?

2539


Thumb rule of cable size(rm>30 rm)X multiplying factor=ampere

1607


How to calculate the size of earth cable to earth the neutral of UPS ?

1927


For a 6.6kV Motor it is recommended to do megger test with 500 V d.c and not more than 5kV d.c but the Hi voltage withstand test should be performed by 12kV AC. Why the dc voltage test should be limited but AC voltage withstand test could be with such a high voltage?

2321


how ups works ? various parts of ups and working principle

1977


i want to learn control schedule for 11kv panel? can any one send the detailed control schedule?

2422


from which formula we select a capacitor rating?

2110


In CTs tan delta point should be earthed , what is the reason behind it?

3020