Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Bhel supervision exam question:
If 2 generators are working in a network. And if suddenly the
field of anyone generator weakens. What will happen in the network?
1. The generator will run as motor
2. The generator will run as motor in reverse direction
3. The generator will take lighter load
4. The generator will take more load

Answer Posted / kalinath

the generator will run as motor beacuse as the field is
weakened the e.m.f devoloped is reduced across it
beacuse of this potential difference there exists a
circulating currents

Hence the resultant is absorbing power of generator

Is This Answer Correct ?    17 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is servo motor and how it works?

2232


What is T’Q and X’Q and X’D ? and what is saturated as well as unsaturated ?

1731


armature winding of dc machine produce alternating emf then it convert in to dc by using commutator.But only we consider armature resistance why don't we consider inductive reactane effect?

2018


how to calculate distance between busbar supporters for LT panel, what are the factors influencing in this design

5239


Difference between shunt, PMG and AREP excitation. Which is the most reliable between PMG and AREP.

9520


Explain Need of a starter in a dc motor.? Also explain any two starting and speed control method of dc motor?

1671


What is the tests required for a 132 kV, 400 kV , 765 kV for a Circuit Breaker and Power Transformer before commissioning ?

1511


why on axial hitting up of air blast on hydrogen produced in oil circuit breaker,temperature rises of the core of the arc?

1909


What are the causes of having an rmu explode after installation? And how do u treat the bushings of an rmu?

2448


In dc ckt. 24v or 110v, which one is more efficient and why?

2177


What is mean by hot and cold loop testing?

1039


what is the reason for indication of light in the earth lamps of main switchboard.if there is an earth why does one lamp get dim and the other two bright.

2289


What will be the voltage regulation of a full load and 0.80 power factor lagging load transformer when a two winding single phase transformer has a voltage regulation of 4.5% at full load and unity power factor?

1171


Why we used 690V in ACS 800 drives.Why dont use standard voltage like 415v or 1.1Kv

2390


what are the stresses in circuit breakers ?

1968