Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How many no of flip-flops are required to get 16 bit counter

Answer Posted / prashant

according to formula
2^n<=N
where n is the power and N is no. of bit for a counter u required.

this implies u need 4 flip flops...

Is This Answer Correct ?    2 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

can i connect REF and Differencial relay in 1 CT core for transformer protection?

2006


What difference between ref protection and differential protection ?

1897


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity?

2019


different aspects of voltage stability

2125


what is a pilot wiring and whys that called a pilot wiers

2004


Difference between shunt, PMG and AREP excitation. Which is the most reliable between PMG and AREP.

9648


State the other types of Air Conditioners?

2125


i want to know how to determine that a surge arrester work properly in 11kv system. and how to test a 12kv surge arrester

2194


i am going to correct power factor of 1600kw induction motor,when i calculate capacitance of capacitor it is three time more in star connection than delta. if motor is star connected which connection i shall adopt for capacitors and reason for adopt this connection

1892


i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.

1979


How Calculet The UPS AH In Load

1952


What is tranformer differtial?

2090


what is the calculation formula for motor starting torque,running torque, running torque.

1730


What is the Diff. btw Manule Pull Station & Manule Abort Station Switches used in FM200 System??

1903


What is dynamo function in DG sets and draw block diagram?

2090