Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is basic difference between Soft Starters And VFD
drives?

Answer Posted / anup patil

The Starting current of motor is very high.To protect the
motor from the high starting current we use soft
starters.VFD's on the other hand are also called as
Variable Speed Drives where we can change the speed of the
motor from 0rpm to motor rated rpm by varying the
frequency.It is mainly used to operate the motor at its
variable speed.By use of soft starters the motor reaches at
its full load smoothly and after reaching at its full speed
it acts as a VFD.

Is This Answer Correct ?    8 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how do prepare ongc exam.how is it question model.i am electrical. which part covering in electrical.tell me

2256


How much load can be taken for chiller from 1500 kva transformer

1263


Give some example of fault limiting devices?

1344


If two Transformers are connected in parallel having impedance of 50KA in both transformers will the impedance increase or decrease after connecting transformers in parallel?

2050


What is the Surge for 1.1 Phase Induction Motor(For Eg.1Hp) 2.3 Phase Induction Motor(For Eg.1Hp) 3.AirConditioner(For Eg 1Ton) 4.Refrigerator(For Eg 180Ltr or 160kW) 5.Induction Cooker 4. Ceiling Fan

2046


what is the formula of starting current of 3phase and 1 phase motor???

2070


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1775


What is difference between YNyn0 and YNyn ??

2541


What is routh hurwitz stability criterion?

1170


I FINISHED MY B.TECH IN EEE . I AM IN NEED OF A GOOD TRAINING INSTITUTE TO DO COURSES .. CAN ANYONE SUGGEST GOOD CENTRES IN TAMILNADU ,BANGALORE ,OTHER AREAS???????

1999


What is essential to prove safe isolation of electrical circuit?

1068


defult setting in p220 micom motor proction relay for 11kv,640kw,f.l.a.-40a,1440rpm ht motor?

3696


hi frnz,can somebody give me any project work? i am a 2nd year student & interested in practical works...plz give me some projects

1988


what happen when increase or decrease size of lamp,light.glass.

1911


how to select the automotive wire size by mathematical calculation. for xenon headlamp with ballast. the ballast given data voltage 10-17v,current permenant 6amp, run up phase is 15amp, peak at swicth on max 400micro sec is 40amp.the sum of cable resistance is 150mohm.please provide referenc document if any for relating the peak at switch on current,time & wire wire size

2372