Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Bhel supervision exam question:
If 2 generators are working in a network. And if suddenly the
field of anyone generator weakens. What will happen in the network?
1. The generator will run as motor
2. The generator will run as motor in reverse direction
3. The generator will take lighter load
4. The generator will take more load

Answer Posted / shankarj23

The generator will take lighter load.. Since its operating in network..

Is This Answer Correct ?    16 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

please give some hindalco placement papers for written exam

1810


TCS IS IT COMPANY THEN WHY DO THEY NEED ELECTRICAL &ELECTRONICS ENGINEERS?

1944


State kirchoff current law?

1088


Why ground terminal is used in pot meter 10k ohms

1888


How two nos. 130 kw D.C motor get synchronise using D.C drive.

2130


I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?

2574


What is the diffrence (Technical & Construction ) between CBCT & Normal CT?

2032


how can calculate 1kva generator running time in 1 liter keroscene

2616


What is superposition theorem?

1194


what is meant by 3rd hormonics ?

1866


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2034


where is core-type and shell-type construction suitable for transformers ?

2093


How to check the cable fault / hv test of transformer cable.

1882


I AM GOING TO ATTEND APTRANSCO ON 26TH OCT 08.PLEASE SEND ME ANY MATERIAL OR TYPE OF QUESTIONS OR EXP QUESTIONS.

1956


please give me all the Alarm .Trip ,Safety Relays & Conditions of UPS Systems mail me on ashokbabunhce@gmail.com

1791