Answer Posted / sunil meena
AMF Means automatic mains failure.AMF panel has wide range of features with generator start,stop,monitoring and protection.AMF panels are used to automatically changeover from mains electricity to standby genset on failure of mains supply.When mains supply is resorted the system automatically changes back and stops the genset.
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
how many safety really of DG sets.
in control panel, how can i measuring the distance between one bus bar to another bus bar. then now only for bus bar. in mpcb and contactor also. that means one mpcb to another mpcb how much distance? how can i calculate that.
How npn and pnp transistor works
brief notes on ammeters
Why derivative controller is not used in control systems?
how we do Vector group ,magnetic balance and tap changer test in Transformer?
What are the reasons for the parallel operation of transformers?
If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a camp site.?
Which do you think is the most significant cause of energy loss in a factory?
what is transistors comprised of?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
How to Decide(calculate) Bush bar size for copper and aluminiam ?
what is method for testing CT
what is a types of short circuit and what is a types of distance protection tests
In Plumbing services What are accessories we consider for a bathroom?