Is it possible to power factor more than unity?
Answer Posted / shahid arafat
power factor = cosine of angle between v&I & angle cannot
be less than zero
cos0 = 1 if angle increases p.f will decrese
cos 30=0.8
cos 60=0.5
cos 0=1 there fore p.f cant be less than unity
| Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
A 2083kva AVR was tested, phase to ground shows continuity, what is the implications
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
Why we use Electrical energy rather than any other type of energy, mostly? Explain behavior of open secondary CT and short circuited secondary PT in energized condition?
What is the estimated total hydropower potential of india?
Why a Permanent Magnet Generator has higher frequency as compared to frequency of main alternator?
What type of a DC motor would you use for a lift?
Hoe do calculate the Cable size for Amps rating ?
what is The difference between national electrical code and I.S.Code (electrical) and what is the value of NEC in electrical engineering field
What are the different types of LT Cables?
Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.
What is the difference between security constraint unit commitment and security constraint optimal power flow?
what is resver in electrical enginnering with answer
we have 2.2kw,Y,3000rpm motor but 6leads found in TB what happen if we connect in delta?
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
A powerplant has 8 gensets operating in grid parallel mode. In one genset sometimes there is pf variation and kvar variation. The plant operates in pf mode. When this variation is observed the load is stable, voltage is also stable, freq and genset speed is also stable. How will you check the functioning of pf card. What shall be the ideal output vdc of the pfc, from there it is input to AVR?