What will be the excat cable specification in Sq
MM...please find the details below....
Induction Motor HP:55
Amps:70(starting Amps),45(Running Amps).
Volts:415
Answer Posted / prakash gokhale
3.5 core, 50 Sq. mm Al conductor, PVC / XLPE insulation
Is This Answer Correct ? | 2 Yes | 2 No |
Post New Answer View All Answers
Swg formulae
what is Insulation monitoring device. where it is used? (in switchgear room or control panel or in field equipment)
two phases with neutral supply can be taken in 3C X 10 sq.mm cable .
why surge protectetor work explain with the help of circut diagram?
what is the profesional board for electrical engineer what is thepast and during construction for electrical engineering
we use 400/5A ct and 35/roor3KV,/0.1/root3KV,0.1/root3KV pt ratio. What is the multiple factor of this meter.
What is the difference between relays and contactor construction wise?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
what is meant by poly phase induction motor ? how its operating by single phase or three phase?
explain remenance . differentiate high remenance type ct & low remenance type ct
What is bode plot?
What are operating procudures & Safety precautions to be observed while operating OLTC in manual mode ?
What is the necessary and sufficient condition for stability.
Dear sir, iam completed iti ncvt electrician 2000-2002 & diploma electrical eng completed 2008-2010 distance education in rvd university, still i got B licences only but my working company want C licences, how to i get c licencese pls reply me iam in critical situation thank you karthick 9841637803