what u mean by speed control in turbin? how it was working?
Answer Posted / banerjeenandan
As the Generator output frequency remains constant usually
50Hz, so we have to control the speed of the turbine in
constant speed. Govorner takes the signal from Magnetic
Pickup Unit (MPU) and operates the govorning valve so that
the turbine rotates in constant speed.
The magnetic pickup unit is mounted on turbine front, facing
the gears of the gear wheel. Generally there remains 2 or 3
nos of sensors which measure the speed simultaneously. As
the turbine rotor rotates, the number of gear teeth cutting
by the sensor increases. This is counted at the sensor
itself. According to this the sensor sends an mA signal to
the govorner. And thus with respect to this, the govorner
takes action to open or close the Govorning valve to
regulate the flow of steam entering into turbine.
| Is This Answer Correct ? | 20 Yes | 0 No |
Post New Answer View All Answers
what is output of FOUNDATION FIELD BUS transmitter
what is the procedure to callibrate temp controller ,pressure controller,etc. suppose a temp controller showing error 1.5 degree centigrate how can i minimize it.
Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.
selection of the zener barrier for the hazardeous area zone 0
Somebody can explain me about >Critical Loops, calibrations, ESD critical Loop checks, Logic Diagram / Cause & Effect checks for ESD loops,
Specify for Cables - Flame Retardant and Fire Resistant?
hello friends, can you please send me the model paper or question paper to be prepared for hpcl examinations????????? You can mail me at rahim_here@yahoo.com waiting for your reply........... help me .. plz.....
How u measure the massflow in orifice flow measurement techniques
What is the minimum rating availalbe for weld neck orifice in market?
TEMPERATURE VARIATION FOR FREQUENTLY.
what is installation and commissioning of (fat & sat) of power plant dcs ? this question keeps in desirable conditions of one company .
what is the difference between scaler and vector drive
where uses EXe /EXd/Exo/Exn/Exp/Exq/EXia
give eg of how I/P is used in control loops
What is Span Error