Questions :-
HR-
Q.1 about yourself & family background ?
Q.2 Why u choose Power sector as ur carrier starting not any
other sector ??
Q. 3 What think abt NTPC ?
Techincal Questions:-
Q.1 about Vocational Training……What u did , see the main
equipments….etc
Q.2 Why a transformer Noise during its running condition ?
Q.3 about transformer oil material & Test name for the
measurement of its dielectric strength & wht will u do if
its dielectric strength goes low ? ……..some discussion type ?
Q.4 What is relation between transmission lines &
Communication lines ?
Q.5 Which Machine u will prefer to use at a place where
flammable gases are coming out & why ?
Q.6 how fault in an electric system is detected & hw
protection of equipments is done ?
Q.7 Why we didn’t feel electric shock in an electric train ??
Q.8 Anything u want to ask from us ??
Answer Posted / deep
pls send me d ans in my id dipak.deopa@gmail.com
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
what is the relationship between current&voltage in practical purpose ?
Can we test the alignment of End shield and stator of turbogenerator without rotor insertion? Also how to fix maintain the alignment at site installation?
What is the fault or needs to be done when frequency in ac drives is not changing?
how to calculate micom relay earth falt time and current sertting
how to put cable sizing and cable glands size for respective cable & Cable Lug size in a DB sectors???
What is the source of dependent source ?
What is rotating magnetic field?Discuss elaborately.
why the check zone and main zone are used for Busbar Protn. scheem?
The 3 phase Delta connection RB=440V, BY=350V,.......* is Line to Line voltage RY= ? And Formula....?
what are the 4 rules to start the motor?
Why neutral is not used in three phases dol starter
An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm
i want to know that what is the eligibility critaria for ongc exam?
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.
why is using sensor?what is differece between photoelectric and proxmitty?