Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How can we get a Neutral from a three phase suply? If we
meet all three phases at a point to take neutral then why
dont thay get sparked?

Answer Posted / shan80

u know that there is two type three phase supply star and
delta. delta connection has three wires. these wire are
three phases only there is no nutral and in star there is
fout wire three for phase and one for neutral. make sure
what is ur connenction type.
and ur idea to connect these phases each other for making
nutral point is absolutly wrong it is a dead short circuit
and become harmful.
whereas the point of neutral in star is junction of only
one end of three different coils (coil of transformer,
motor or genrator etc.) and other ends representing three
phases.
i think u should clear with that.
thanks.

Is This Answer Correct ?    17 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is transient stability analysis means?

2083


What are the Full Forms of TVM, MTL, CVT ?

1378


What is dc current source? Differentiate between ideal and non ideal current sources?

1386


What are the characteristics of negative feedback?

1004


What do you understand by external characteristics of a d.c. Generator?

1062


What is the permissable nutral current of three phase system as per IS standards?

2043


Post possible questions for Power Factor Panel FAT / SAT

1362


lenz law application and define

2769


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING) I O (current operating)?

2155


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%

1850


Vibromotor 252MV 1/4HP2P..what is mean by 252MV?

1900


What will be the effect if I use inverter as UPS mood?

2141


how to produsing geretor power

2150


how to get electrical supervisor competency certificate in gujarat. i did 3 year diploma in electrical

2520


What is servo motor and what are the applications of servo motor?

2643