working of a diesel generator.
Answer Posted / p.viswanath rao
Diesel Generator is a set of engine and alternator.
(Which converts mechanical energy in to electrical energy)
here engine is using for rotating the shaft(prim mover or
crank shaft).
Rotation takes place as fallows:
1)The pistons placed in cylinders and these pistons are
connected to Crank shaft through connecting rads
2)By using diesel as a fuel the blasting takes place in
cylinders, this blasting energy can be converted in to
rotation through piston,connecting and crank shaft
3)this rotor speed strength(should be synchronous
speed)depends on firing order of the cylinders (of course on
number of poles on rotor)
4)this shaft is connected to Alternator rotor
5)this rotor contains poles, this rotor will get the D.C
supply from A.V.R through Exciter (RRA: Rotating Rectifier
assembly, it is a converter bridge)
6)So with rotor(poles) rotation the EMF will induce in main
Stator(Faraday's law of electro magnetic effect)
7)A.V.R out put depends on load effect on D.G.
((for further full detail call me at 09458490849)
| Is This Answer Correct ? | 53 Yes | 5 No |
Post New Answer View All Answers
What are the raitings of Mcb,mccb and Acb in detail ??
what is the maximim current drawn by 1 phase and three phase welding machine
Mention the methods for starting an induction motor?
WE HAVE THE DC RECTIFIER 1500A, INPUT VOLTAGE IS 3 PHASE. HOW TO CALICULATE THE LOAD? 3 PHASE SIDE EITHER dC SIDE. PLEASE SUGGEST ME
Why it is necessary to isolate fire fighting when you are taking shutdown for lv board.
explain single phase series motor
what is the diference between the 4pole & 6pole DC Motors & what is advantage 6pole over the 4pole ?
How to address the servo drive for motor
how to synchronize 3 phase slip ring induction motors of different ratings.
What is the different between conventional MCC and intelligent MCC? Common controller or controller for each bucket
I PURCHASED A DEISEL GENARATOR SET OF AVR TYPE& RATING 125KVA BUT SOME TIMES THE OUTPUT VOLTAGE IS FLUCTUATING WHAT ARE THE PROBABLE REASONS GIVE ME
I WANT YHE TECHNICAL AND ELECTRICAL SPECIFICATIONS OF 2x4MW 11KV 2x10MW 11KV 2x25MW 11KV 2x100MW 11KV HYDEL POWER PLANT i.e PROTECTION SYSTEM,MONITORING,CONTROL SYSTEM,GENERATION,SYNCHRONISATION,METERING PLEASE SEND THE DETAILS TO MY MAIL ID SPRAVEEN_222@YAHOO.CO.IN
11 kV line deraction check by an Engineer.
is there any current and voltage drop on liquid resistance starter water/soda tank ?
what will happen if ac and dc supplies given