Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what should be the megger test report for 11KV cable when
meggered with 5KV megger , what is the resistance value we
should get

Answer Posted / velusamy

min of 11 megohms

Is This Answer Correct ?    5 Yes 10 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have 1500/1A CT If i connect this CT in 6.6KV bus bar means what will be the voltage present in CT?

1995


How to calculate multiplication factor in kva example 500kva ans pls ?

1949


What is the effect on power factor, shown by a trivector meter; incase of reverse phase sequence. If the power factor of a system is lag what meter will show in case of reverse phase sequence connected to the meter. and What in case of lead.

2310


A cylindrical wire is compressed in length by 10%. The percentage decrease in the resistance will be?????

2257


Why the earth to phase voltage is high 250 compare to other two phases

1510


for 4 MVA , 33K.V/6.6K.V transformer. secondary side the connected load is 3000H.P. What is the rating of capacitor bank to be insttaled.

2572


what is the mechanism of operation of brushless dc motor why is it more wexpensive then ordinary permanent magnet motors

1997


how we can decide that what value of ht line will come to any commercial building? (ans except According to the building load)

1650


any one guide me to reduce the power factor of diesel Generator from 0.97 Leg to 0.8 Leg.with out any change in my load.

1667


Why is better to have a minimum ceiling voltage of 250% than 160%?

1838


A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?

5257


What is the general system requirement of alternator?

1841


what is the purpose of slope in the differential relay?why we are using two slope?but in busbar differential we are using only one slope.why?

2905


I PURCHASED A DEISEL GENARATOR SET OF AVR TYPE& RATING 125KVA BUT SOME TIMES THE OUTPUT VOLTAGE IS FLUCTUATING WHAT ARE THE PROBABLE REASONS GIVE ME

1827


If any cable burnt how can we identify it burnt by high current of high voltage? 