Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the difference between venturi and orifice meters?

Answer Posted / k.srikanth

1.The major difference between venturi and orifice meter is the time taken for water collection in measuring tank (size of tank minimum 60 ltrs )is more in venturimeter when compared with orificemeter.
2.The cost of venturimeter is very high compared with orificemeter.
3.The cofficient of discharge is more in venturi than in orificemeter.

Is This Answer Correct ?    90 Yes 13 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

For crude application in floating roof tank, how to calibrate a DP Transmitter? How is the floating roof weight considered?

5510


What is cut off relay? And why use in PLC and DCS?

1413


Calibration procedure for water rotameters

2237


What is the use of each wire in three wire RTD

2541


A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?

1456


What are de-saturators?

1291


dear friends, i have seen flow as the selection critriea in presure guage (bourdon tube) and i would like to know what is the relation between flow and performance of pressure guage other parameters i found in the data sheet are pressure max. 1ksc temperature max. - 50 deg c line size - 80NB operating range - 1ksc pr. guage range - 0-2 ksc thank u,

2215


what is the difference between -24 : +24 & 0:24 and where it use?

2122


how can we tune a PID. If it is by zeiger nichols method..please explain briefly with help of an example.

2516


What denotes the 5/8mm in the 3300XL 5/8mm proximitor probe?

1456


Where Can i take a SPI INtools training in Mumbai? In Rolta India Ltd to whom I should approach regarding of SPI INtools Training?

2825


What is heating effect?

2407


In bently nevada vibration monitoring system,what is the reason to maintain the Resistance of the probe + extension cable equal to 95 ohm? If possible explain the basic principle of measurement with detail electronic circuits.

3006


Explain an adaptive / self-tuning controller’s major draw card.

2382


What is loop1 and loop2 in MTS LT?

3897