Answer Posted / balaji
APFC panel is for automatic power factor correction. in some cases of industrial applications the loading pattern of the entire network of the industry will change time to time. so if you connect a fixed compensation. it will not be in position to compensate exactly what is required. but in case of APFC panels you will have a microprocessor based relay which helps you to sense the load current instantaneously and the particular MC relay will hunt for capacitors to compensate and power factor improvement will be automatic.APFC is nothing but steps of capacitors connected to the contactor in turn connected to the breakers and relay.It doesnt require much of the manual support as of fixed compensation is concerned. Your power factor will be improved automatically, APFC will have a step by step compensation.
| Is This Answer Correct ? | 29 Yes | 9 No |
Post New Answer View All Answers
What is the previous name of Cox's Bazar
What kind of maintenance is conducted for Transformer
calculate external resistance values to add to the rotor of a slip ring induction motor. STATOR- 415 V, 3 phase delta, 1100 A, 50 Hz, 1490 rpm, pf 0,86 ROTOR - 660 V, 590 A, 50 Hz. STATOR current at each steps STEP1-600A,STEP2- 800A,STEP3-1000A,STEP4-1100A.
anyone please send transformer parameter design formulas & details of tap changer ? plz i have interview this week its more helpful for me ?
How many types of colling system it trformers?
Describe the control mechanism of missile launcher???
ow can i get certificate of competency as electrical supervisor and my diploma in electrical engineering from jalgaon.
formula for calculation of switchgears(i.e. contactor, fuse, cb, relay etc.), if load current is given?
What are stable systems?
How to design the NGR Resistance
Hi,iam a diploma in electrical engineering.rtd from indian air force in apr 2007.prsently working in reliance next link as a network maintenance engineer since 2007,can i get a job in motherson sumi.
Give the expression for the frequency of oscillations in an op-amp sine wave oscillator?
We have received supplies of the ordered material. payments against the supplies also released. Where ST paid 4% against form C. Meanwhile it has been observed that 25% of material supplied was defective. Please suggest whether the issuance of C form from our side would be stopped till settlement of liabilities.
Can any body tell me about INNER SHUNT COMPOUND MOTOR diagram?
what is the terminal voltage of dc series generator running at rated speed at no load?