Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is use of thermistor ?

Answer Posted / ankit dhyani

thermister is a resistor which is negative coefficient of
temperature.
when temperature is increased, resistance of thermister
decreasas and when temperature is decreased, resistance of
thermister increasas.
thermister can be used for temperature controlled
pperations.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why 30kw 40 hp 4 pole 3ph induction motor over heated?any steps on reduction in heat?

1666


11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter

1920


What are the factors influence the choice of an electrc drive?

2076


what is the mechanical safety of DG ?

2157


what is power factor ? how we can calculate the low power factor and amount of capacitor for improve that low factor ?

1607


Can we use both Electrical & mechanical interlock between tow breakers? if yes how, please explain

1495


1.why we are using metal oxide gapless block in lightning arrester,2.What is minimum and maximum rating of metal oxide blocks using in india

1957


what is the safety points of vaccum circuit breaker.

2081


what is difference between 9kv 5ka surge arrester and 9kv 10ka surge arrester.

1851


Ratings of power transformer,Distribution transformer.

1602


how to CHECK CT AND PT AT THE FAULT OCCUR IN GENERATOR RELAY PANEL .

2275


at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.

1661


What is the limitation of kirchoffs law?

1121


What is meant by Low Resistance Cable and High Resistance Cable.

1903


Explain what are inter-poles and why they are required in a dc machine.

1081