Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Brushed alternator is also called dc generator ? its true
or false ?explain it ?

Answer Posted / thuranga

I exactly does not know the right answer for it...but what I
think is ,in the alternator the AC voltage collected at
sliprings where it turns out to be ac becoz there will be
not breaks as on commutator(for DC gen/mot)

so as far as I know if the alternator consists the mica gaps
on the shaft or commutator then it acts DC gen....
but without those gaps even if we put the brushes also the
current collected at brushes will be ac only.but the only
problem is the maximum power will be wasted at the brushes.
(this is my view,tell me if it is wrong).thanking you

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the different types of hydro schemes?

1312


How to calculate the fuse rating depend upon the DC circuit?

2913


Name two types of electrical analogous for mechanical system.

1275


can we start slipring motor on star delta like we start induction motor ? if yes where will we connect ?

2000


Which is the oldest hydropower plant in india?

1205


Write the current equation in series RLC circuits.

1174


How to calculate the heat load for a electrical room

3138


If Dg set load increase 25%, How much increase fuel Consumption (15 kva 2 cylinder DG set)

2320


Is it posible to instal one more SMDB from the existing SMDB and is it practical.

2161


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm

2360


Where voltage are high and current to be interrupted is low the breaker preferred is:

2338


explain supply side and demand side energy management with advantages & disadvantages

2189


What will be the effect if I use inverter as UPS mood?

2241


when qty of cable being purchased is not sufficient according to the standard,what should the inspector do to ensure its quality according to the standard?

2114


When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number

2224