Answer Posted / santosh kawade
Transformer is a passive device hence rating of transformer
is always mentioned in KVA.
Transformer itself is not a end user of electrical power
(it do not consume power), it is only media of tramitting
voltage levels.
Power factor at transformer terminals (primary or
secondary) is depends on power factor of loads connected at
lower end, hence rating of transformer alway mentioned in
KVA.
santosh kawade
9224 69 3116
| Is This Answer Correct ? | 0 Yes | 3 No |
Post New Answer View All Answers
What are the Formula of computing Back up Time of 500kVA UPS with 4 Battery Banks, each bank composed of 43 pcs of Batteries 12V150Ah. How to compute the Back up Time of UPS? We have also 3X500kVA UPS running in Parallel same composition as I write above.
it is in our knowledge tht right plug of supply of residential suppy system is phase n other is neutral...howevr the battery charger of mobile works in both ways...i mean it is not restricted in only one direction.ny of the holder of charger can hav phase .so y is it not lik tht phase of supply must b connected 2 phase of charger...?
11 kv input, 66 kv input advantages
How one can check the MAIN of a house wiring ?
what is the meaning of 5% droop or 7% droop in AVR?
5- What is the task (function) of the excitation and isolation transformers in power plant? 6- What is the task (function) of LCI (A), LCI (B) and LCI (COS) in power plant? : LCI (A) and LCI(B) are load commutating inverter for generator turbine starting. , LCI (COS) is load commutating inverter change over switch
When are the directional relays used?
either water sensor or flow meter,how we observe the water level, f any other equipment are in market ?
Anybody tell me about modbus hex address of l&t trivector meter er300p??I want to read voltage,current,kwh etc via rs485...If anybody have a manual then send on my mail..Brijeshmodi18@gmail.Com
what is the difference between changer, converter and transformer?
Either It Possible a dc Motor to Run On Ac Drive [ Ex : ACS 800 , Yaskawa F7 ] If it is Possible How Pls Inform Me dinesh_elect_eng@yahoo.com
what is the benefit of floating our DC source? if i have two floating DC source of which 1 has a ref voltage of -21VDC and the other of -18VDC. can it be connected in parallel to share a common ref voltage? if not, how do i make both sources to be of common ref voltage? tks
What is Percentage impedence of a transformer? why it is expressed at a percentage? what is the importance of percentage impedence in case of a transformer?
what is the principle of operation of CFL ??
Dear all i want to know SEWA Electrical Supervisor Licence test Previous Year Questions ? If any body know please send to me zohairaukllah@yahoo.com