Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the pperating squvance in transmission line for
circuit braker, isolater & earthing switch.

Answer Posted / krishnappan

in switchyard first our earth switch should be open.
after that close the bus isolator,then line isolator.
finally close the circuit breaker

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Capacitor is load free component but why ampere meter shows current when capacitor bank breaker close?

1189


Explain Active power,reactive power,how its related to each other , & inductive ,capacitive.

1925


please send privious years question papers of jindal steel and power ltd.My e mail id is rajanikant.sngh@gmail.com

2094


how can found motors folt current ? how can disided circuit breakers caoicity and breaking capicity ?

2160


what is the standard values(Megger test) of resistances between L&N,L&E and N&E for a system on IEE regulations?

2260


what maximum range of star & delta in hp or kw ?

1689


if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1871


how to calculate cooling requirement of datacentre from electrical load?

2399


Hello to all, Please someone can send me HPCL ELECTRICAL Engg. Sample papers to me? Its urjent....my email address is.... raviasiapacific@gmail.com

2132


I am inpecting a 10kVA UPS what tests should i do and should i observe?

2213


what is the usage of microcontroller in the panel board?

2081


what is the safty of poly phase tranformer?

2125


What is the difference between single core 2 wire and single core 3 wire system? Which application we are using this? and for What purpose we are using this?

2337


33kv substation lay out details & line to line & line to earth measurements

2615


why would the rotor rotate at sub synchronous speed against the direction of rotating flux when d rotor of 3 phase IM is connected to 3 phase balanced supply and the stator windings are shortcircuited ??

2033