WILL THE PERCENTAGE IMPEDENCE FOR A ONAN TRANSFORMEER BE
THE SAME COMPARED TO ONAF TRANSFORMER OF SAME RATING???
Answer Posted / gunasekaran
as per standard it is not same cooling is depending upon
the rated MVA percentage impedance depending upon the MVA
rating if low MVA %impedance is low if high MVA %Z is high
in standard upto30MVA we can use ONAN
upto60MVA ONAF
above 60MVA we can use OFAF
upto 1.5MVA AN
if customer asking we can use for colling method for any
rating.
| Is This Answer Correct ? | 6 Yes | 3 No |
Post New Answer View All Answers
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
Haw to check conductivity of budbar
Hi,iam a diploma in electrical engineering.rtd from indian air force in apr 2007.prsently working in reliance next link as a network maintenance engineer since 2007,can i get a job in motherson sumi.
What are the temperature elements?
working principle of AC Servo Motor with its construction
how can i find cable size from current rating?
In electrical what is earth(ground)connection, wht is the importance of it, why it is recomended to maitain below 3VAC between Neutral and earthspecially in PLC used machines?
what is the effect of change in supply frequency on load angle of synchronous motor,all other parameters remaining same?
In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.
why Y CONNECTION IS BETTER INTERMS OF EFFICIENCY AND P.F FOR A LAOD LESS THAN 40% AND WHY AFTER DELTA IS BETTER FOR > 40%
I need to connect a synchronous generator to the grid using automatic synchronization and two circuit breakers (one for synchronization, one for end connection to the grid), how to determinate the required diameter of the cables?
Define the term factor of inertia.
5.WHICH TYPE WELDING PROCESSES USES NON CONSUMABLE ELECTRODE.........
Why does the radius of armature is less than the radius of pole shoe?
Sir, I have applied for the of Assistant.engineer of NPDCL. please send me all AP TRANSCO AND JENCO solved papers of previous exams . I requested send me the papers to my id as soon as possible (rajanikanth_peddi@yahoo.co.in) (This is very urgent) Thank You,