Answer Posted / alianwar
MOTOR : An electric motor uses electrical energy to produce
mechanical energy, usually through the interaction of
magnetic fields and current-carrying conductors. The
reverse process, producing electrical energy from
mechanical energy.
PUMP : A pump is a device used to move fluids, such as
gases, liquids or slurries. A pump displaces a volume by
physical or mechanical action. One common misconception
about pumps is the thought that they create pressure. Pumps
alone do not create pressure; they only displace fluid,
causing a flow. Adding resistance to flow causes pressure.
Pumps fall into five major groups: direct lift,
displacement, velocity, buoyancy and gravity pumps
| Is This Answer Correct ? | 8 Yes | 1 No |
Post New Answer View All Answers
Why a Permanent Magnet Generator has higher frequency as compared to frequency of main alternator?
Why does curving the pole faces in a dc machine contributes to a smoother dc output voltage from it?
how to measure earth resistance of a substation
need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.
How to do fabrication , busbar and wiring cost for : 1. LT Panels 2. C& R Panel
can anybody tell me that for p.f. Improvment we use capacitor banks but how to decide its capacitance. As we all know how to calculate kvar but what abt capacitance value
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.
why generator efficiency is more in swinburnes test?
I Have 3 Phase 10 KW AC Alternator i found one phase weak, so what will be the reason & what action shouls i take to rectify the same.
Why are short circuit ratings always 16kA,25kA,36kA and 50kA.Who has fixed these?
why using transformer and thyristor switch in 3 phase apfc panel
Define peak time.
how we start 40w tube light with 4 diodes,2capacitors,1 choke and without starter.(a product avilable in market which lights burnt tube lights also)
how to setting voltage RTCC panel