Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the effect of connecting three phase supply lines
to three phase auto transformer output terminals through a
fuse of 10Amp and a circuit breaker (MCB). Is this
connection permanently destroy the transformer?

Answer Posted / guest

1)Why would you want to connect the supply lines to the
output of an autotransformer?
2)The reversal of what you have chosen will happen. that is
if you had connected the higher than normal tapping of the
transformer with the supply than you will get a lower supply
at the input side.
3a)The 10amp fuse and MCB connected depends on how big is
your autotxformer.
3b)When you connect an MCB OR a fuse to a 3 phase
transformer and if one of the fuses or MCB breaks than single
phasing happens in the circuit which is not good.If you must
protect use a three pole reliable MCB only.

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the effect of vector group while phase sequence of a generator changes,whether the vector group changes or not

2094


when we have to purchase the transformer by own i.e how much load will preferred HT connection?

1664


1.what is mean by 8/20 micro sec waveshape

2221


Write the force balance equation of m ideal mass element.

1239


HOW TO CALCULATE ELECTRICAL, MECHANICAL,& OVERALL EFICIENCY OF GAS ENGINE POWER PLANT

1995


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2206


Maintenance of transformer???

2253


draw vector diagram and +ve,zero sequence diagram of symmetrical three phase fault.

2024


For overhead protection we use which transformer?

2479


th how could we differentiate between armoured copper and armoured aluminium cable what is the basic application? why we prefer the armoured copper as compared to armoured aluminium.

1956


bsnl tta exam question

1869


how can we save enegry by using VFD for Resiprocating Air compressor which is having more unloading running hours

2283


i had aplied Hindustan Petroleum corporation limited for the post of maintenance technician -Electrical,i want model questions,if anybody have please send it or please advice?

1867


Is single load(eg: three phase motor) having all the components like positive,negative,zero sequence components during fault condition?

1806


what is the formula for efficiency of francis turbine and generator for hydropower? what is best way to select francis turbine and generator?

2490