why we are doing post tensioning in beams and slabs.
it is economical compare to rcc? how?
Answer Posted / vikram jain
Dear Friend,
It is very economical as compared to RCC.
1.) Early Post-Tensioning allows the formwork to be stripped and re-deployed quickly. Significant saving on material, up to 30% on concrete alone with longer spans, fewer columns & thinner slabs producing lighter overall structure and reducing foundation cost.
2.) Joint free ground slabs up to 10000 mイ and true & level floor – ideal for automated ware housing and super markets.
3.) A facility to span over poor ground conditions with full resistance to mining subsidence.
3.) Water proof floors to eliminate unsightly staining of concrete fascias. Thinner slabs give more head room.
4.) Flexibility- Internal layout flexibility is greatly increased, making it much easier to place or reposition partitions with formwork stripping and redeploying quickly and with less steel & concrete construction work is faster than R.C.C. construction.
5.) Spans up to 50% longer than those using RCC can be constructed with fewer support columns.
6.) Offers resistance to cracking and water seepage due to limited deflection and highly compressive characteristics of prestressed concrete structure.
7.) In Post Tensioned slabs, slab is always tested for stresses that are supposed to be come on slab.
8.) Thinner Slabs – post tensioned slabs of thin concrete plates may be used to reduce storey height in multistory buildings.
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
Why does the pressure increase under soil?
What is absolute pressure? How absolute pressure is calculated?
Test procedure of fly ash bricks as per code ?
Which is the direction of negative angle?
I Want To Know Quantity of Cement Conc. & Sand in Column of 9"x9"x10'
std penetration resistance in very stiff clays lies bet 2 & 4 4 & 8 8 & 15 15 & 30
i am completed my b.tech EEE in 2009,,,iam trying the job 3+ for AUTO CAD (ELECTRICAL),, what is the market for autocad electrical in hyderabad... how to handle the intervws give some suggestions ?
column at edge of a framed structure is uniaxial or biaxial. and is an interior column is biaxial
why is M30 grade Concrete use for Foothing & Column M50
how many running meters in one kilogram of 4mm pvc coated chainlink fencing
What does a construction cost covers and what does not?
The foundations are placed below ground level, to increase?
I am practising engineer. I am searching for tutorial of RCC T Girder design Example in staad pro.Do anybody has this?please help
Ratio for 4500 psi concrete
What is the primary difference between adsorption and absorption?