HOW MANY EARTHINGS REQUIRED FOR GENERATER
Answer Posted / gunasekaran
their are two system earthing at single voltage level in
generation one is generator neutral another one is PT
earthing and body earthing also provided
Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
it is possible to rotate the DG engine dc starter with wrong polarity connections? why?
How does "OUT OF STEP" relay ,for Synchronous motor protection, work?
how can we save enegry by using VFD for Resiprocating Air compressor which is having more unloading running hours
What is CCT (Correlated Color Temperature) ?
what is the safty of poly phase tranformer?
Why can't we parallel Voltage transformer secondary circuits?
I want the details about BHEL company examination.Can anyone able to help me please.
How we can calculate the consumption in kwh of motor on basis of kw @100% load, @50% load & @ no load.
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
What kind of preventive maintenance are there for transformer?
when qty of cable being purchased is not sufficient according to the standard,what should the inspector do to ensure its quality according to the standard?
how to calculate the lightning arrester conductor @ no of earth pits required
what is electrical machines
When steam condenses and becomes water at the same temperature, the specific heat for the process in kJ/kg k is
Can we check ELCB constantly from R1 to R8 phase in 1 no DB?