Answer Posted / eugene
Speed control control of induction type motors (also known
as squirral cage motors), are mainly achieved by
controlling the input voltage to the motor terminals. This
can be done by altering the frequency of the supply by
using a Variable Speed Controller, or if the speed control
is allowed to be multi-staged, resistive circuits can be
inserted using contactors and resistors, thus limiting the
voltage applied.
| Is This Answer Correct ? | 10 Yes | 3 No |
Post New Answer View All Answers
i have install 750 kva distribution transformer at my site and want to do neutral earthing. what calculations should i follow to determine earthing conductor material and size?
What is big transformer parts and their function ? Ty
1sq mm dc powr cable can carry how much dc currnt
what is the IEC standard for Power Cable installation in onshore (like in direct buried ground or above groung)
what is earth-fault?when it occurs? to check where it occurs what type of test should we do?
hello everybody. what does an abnormal stator winding impedance or dc resistance show? thanx
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
Define damping ratio.
HOW CAN YOU CALCULATE PRACTICAL EFFICIENCY OF A ASYNCHRONOUS INDUCTIONMOTOR OF 7.5KW,& MOTOR IS RUNNING WITH AVOLTAGE OF 410 VOLTS,& TAKING CURENT OF 13 AMPS
Why HT 11 KV Slipring Motors are connected in star ?
A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03
As we know induction squirrel cage motor torque Directly praprortinal to applied voltage in star connection & delta also. If I connect 55KW Motor to DOL starter in load condition does motor withstand the load & what will be the current withdrawn ? motor will not fail ?
WHAT HAPPENED DC SERIES MOTOR FIELD WINDING OPEN. CAN POSSIBLE.
What are the types of excitation system?
Explain what is rated speed?