Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

if the t/c o/p is 4-20mv then how plc recognize it
because we are dealing with the 4-20ma in the
plc ????????????????

Answer Posted / arindam

why we require a 4-20 mamp for transmission? the main reason
behind it because of electro magnetic interference the
voltage can get interfered very easily and we can't get our
desired o/p value.when we are using 4-20 mamp this problem
is solved but since, PLC is a digital device it can
understand mainly High=5V or low so we design the sink to
have a resistance as high to get the desired voltage, the 4
mamp is also helpful to power the electronics at the
transmitter end. to have a 4-20 mv instead can firstly :
cause em interference and secondly we need to have a
continuous level monitoring for different voltages...which
can increase the size of PLC . Also because of change of
impedance at the transmission line the voltage can drop
below 4 volt ocassionaly then loop powering of field
instrument will not be possible.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?

2201


-/5A. What is the meaning and limitations of this in energy meter constant. It is a 3 phase LT Energy Meter. If this Energy Meter is connected through a CT of ratio 200/5 Amps, then what is the multiplying constant and how its will be calculated.

2443


what is the difference between magnetic flow meter and mass flowmeter

1518


Can anybody tell me how to select the size of earthing cable for DCS & PLC system.Please tell me any relevant answer here or mail it to me.

2183


what is the PC interface and software for connection to ABB logic module “ LM011-CE18RAC “ ( for Programming ) ??

4006


What is limitation of the ht.of the displacer of a level trol?

2389


Which type of diaphragm use in costic line, dm water line, natural gas line, oil line?

1164


what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????

5014


what deference between panel earth and systemearth

2318


How ejector(or)evactor air pump is working in thermal power plant?

6592


What is the difference between PLC and DDC?

2175


Definition of reverse and acting controllers:

2305


What is the diffrence between digital signal processing and discrete signal processing?

1977


Hi my friends Is any one who can assist me in knowing the typical interview questions for system engineer at General Electric pty Ltd

2105


Give an example where you had aproblem on the job, and tell me how you solved the problem. and the finalvoutcome.

2237