Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is tertiary winding in transformer?What is its purpose?

Answer Posted / manikandan

If the abnormal condition (unbalance condition) the tertiary
winding is using to give a balance load.

Is This Answer Correct ?    10 Yes 25 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why US countries maintains 110v and 60HZ

2185


Instrument connected to a single phase supply

1696


We have 110Vac ,10A ac supply which is converted into 110VDC & How much DC current? which factor is reqired for dc current calulation?

5150


in single phase converter, the no.of scr's conducting during overlap a)1 b)2 c)3 d)4

2070


what is the minimum requirement gigaohms for the insulation test using 5kv in 300mm xlpe cable

1979


How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.

1746


i am going to give the JSEB,RANCHI exam for power plant,so i need some samples of papers related to that,so please send me these papers by my mail id.

3479


How to calculate multiplying factor of dc energy meter

1665


DRAW ACIRCUIT DIAGRAM OF 100 KVA 415V/55-0-55V DELTA TO STAR TRANSFORMER

2045


LET ME NOW MORE ABOUT icu and ics for circuit breaker. how we calculate the rating of circuit breaker and i c u and ics values

2875


ratings of lightning arrester

2048


How to operate a ac chilar plant?

2484


HOW can i REuse the fused MLL LAMPS & GLS LAMPS at our factory

1900


diff b/w elcb and rccb

2300


Metal covered multiconductor cables shall employ a marker tape located within the cable running for its complete length in lieu of cable surface marking. Is it true or false?

2267