what is meant by dielectirc medium?
what is the dielectirc value of air and water???
Answer Posted / sagar hingmire
Dielctric medium means a medium which is partially a
conductor & partially a insulator.
Take example of Air as dielectric medium,up to 30 kV air is
a good insulator but beyond 30 kV air acts as a
conductor.That means dielectric value or Breakdown voltage
(BDV) of air is 30 kV.
For water as we know water is very good conductor of
electricity,Heat so water is not a dielectric but it is a
conductor.
| Is This Answer Correct ? | 17 Yes | 0 No |
Post New Answer View All Answers
Does outdoor isolator loose connection cause short circuit current in that circuit? if yes then how ??
by using pump duty, how we will can calculate the motor duty(KW)? is there any standard or formula.
What is distance between electrical panel to land ?
How can I calculate per unit (KWH) fuel (Gas/ Diesel both) consumption 1MW unit?
what is the mechanical safety of DG ?
a 230v transformer with step down ratio 19:1.it has 2000turns on primary and rated 25va calculate max primary current no of secondary turns volts/turn
WHAT IS AIR GAP VALUE IN MM FOR A 11KV BUSHING OF 11KV/440V DISTRIBUTION TRANSFORMER. AND AIR GAP VALUE OF 25 KV BUSHING OF AT TRANSFORMER OF 25 KV TRACTION. WHAT IS THE CALCULATION FOR THE AIR GAP PERMITTED FOR BUSHINGS AT DIFFERENT VOLTAGES.
what is the id1 & id2 setting in differential protection relay of CSPC?
Why need 3phase machine double earthing?
how can calculate 1kva generator running time in 1 liter keroscene
Single line diagram for dbb (double bus bar)system.
What is ignition module of a CAT Gas Genset G-3508 Engine, Alternator SR4B Series. HOw its checked for correct functioning.Is it repiarable or replacable?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
How cmd is calculated in case of energy neters
what is the voltage regulation for unity and zero power factor?