How Honeywell FSC is functioning and what is its purpose?
Can we bypasa it and only use DCS instead of that.
Answer Posted / abdul qadeer
you shouldn't bipass FSC because it has its own unique
functionalities apart from normal DCS.it is actualy
designed for some important purposes and only some students
bipass the exam after doin FSC........
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
Why thermo wells are used? What materials are used in thermo wells?
How to erection of DCS Panel at site step by step
Can anybody tell me which type of question are asked in the interview for the FORMULATION(Pharma) as a instrumentation engineer, & question in building managment system.
In Safe Guarding test what means by "Failed to Danger" ?
key exchanges in wpa,wpa2,tls
what is the advantage of submersible level transmitter compare to ultrasonic level transmitter?
what is a good line as ic engineer as maintenance ,oc, project, calibration ,validation engineer?
What is Predictive Maintenance
What is the Working principle of Dozing valve?
which type of signal used in instrument?
What are primary elements of measuring pressure? Which type of pressure can be measured by these elements?
send me model hpcl questions pleas..........my mail id mohideen.dharvesh@gmail.com
What is the difference between mmwc and mmwg?
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
what will the sending unit in the fuel gauge utilizes?