why the single phse machine can not run by the three phase
supply.
Answer Posted / visakh.t.v
Single phase motors are desined for work only in single
phase supply , that is It conist of two windings. starting
winding and running winding.They are arranged in 90
electrical degree degree phase shift. And the input cables
are only two for phase and neutral.But in the case of Three
phase motor consist of Three windings they are arranged
in 120 electrical degree phase shift.and 6 No.s of input
cable for connect either star or delta.
| Is This Answer Correct ? | 10 Yes | 1 No |
Post New Answer View All Answers
in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?
How to identify the start and end of 3phase 12 lead motor if U1, U2, etc numberings are lost or erased.
Can you explain about Restricited earth fault protection scheme
write down the formula of cable size in RM if current is 50Amp.
what is the relation between size of the anteena and wavelenghth of radiated wave
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
Hello sir i m student of gtu .what is idp.
How many energy meters can be connected on a 15VA Voltage transformer. please send a calculation sheet.
what is the major difference between LIBBP & HIBBP.. which one is most preferable..
What is meant by Low Resistance Cable and High Resistance Cable.
in general it is observed in power stations, the tertiary winding is used in higher rating Y-Y auto transformer but not in Y-Y power transformer. is the tertiary winding is compulsory then why it is not using in power transformer
we have consol make 3 phase servo stabilizer for cnc m/c. while installing the earth neutral voltage is 1.7 volts at stbilizer off condition and when stabilizer get on en voltage reaches 4.8 volts (new earthing is done and neutral is helthy condition all phase to neutral volts 440,442,441 v)why this happen.solution for cause.
What is the operating principle of turbo-generator.
electrical
TELL ME WHAT IS INDUCTOR AND CAPACITOR WHAT IS IT BASIC OPERATION ANDFUNCTION?