what r the different types of instrumentation cables? give
their specification?
Answer Posted / tyrkrv83
Instrumentation cables such as Pair,Tried,Individual etc.
All made up of Aluminium polyester tape and ATC drain having Tin-copper bridging, these wires are available in armoured as well as unarmoured cables. These Cables facilitate smooth communication of Low Level Signal from Electronics transmitters.
K.Vignesh M.Sc
Thiruvaiyaru
Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
Explain why plc require in analog input 4-20amp & 0-10 volt?
In turbine what does term CDP, NH, HSSOC means.
Can anybody tell me how to select the size of earthing cable for DCS & PLC system.Please tell me any relevant answer here or mail it to me.
In turbine what does term CDP, NI, NH, HSSOC means.
How to Calibrate Level Troll in field
who's take first position in process in the timing of new installation flow transmitter and control vavle. give the answer with logical trick.
what does it mean an active front end in vfd plz explain it briefly
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
detail of mass flow meter pricipal
What is profibus?
Punj lloyd is coming in our Jadavpur Universtiy campus for campus placement. Please send me some hints about the writtend exam. My email id is subratafriends@gmail.com
Why even multiple power supplu r used in instrumentation system?
What types of Instrumentation Related Questions can an Interviewer ask in a Telephonic Interview ?
Which products are available in the Mass Systemswitch and System Manager AC range?
typical loop drawing of a simple feedback control comprising of one transmitter and one control