Answer Posted / suthanprabhu
1.Body earthing
2.Neutral earthing
3.Winding Temperature
4.Over current protection
5.Over/Under voltage protection
6.Over/Under frequency protection
7.Earth fault protection
8.Reverse power protection
9.Loss of field protection
Is This Answer Correct ? | 40 Yes | 2 No |
Post New Answer View All Answers
given data are load current & power factor cable core size? plz any one update the calculation formula
what is the difference between surge protection capacitor and surge arrestor
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
I have a CT meter with ratio 60/5. The meter reading of previous month was 3290.49 and that of current month was 3797.26. How many chargeable units as per normal meter should be my reading.
surge tank, hrc fuse, earthing transformer, firm power objective type
how to select size of hardware for linking aluminium busbar is it depend on area of busbar or current flowing through bus bar
i need to give section engineer (electrical engineer) for RRB. Please suggest some book
how did i get the competency certificate as electricle supervisor. iam completed my b.tech.but i dnt have any experince, this certificate is required for applyng ongc mangement trainees. what should i do sir please suggested me
How many capacitors using in LT panel as per Govt rules?
Generation of voltage for each phase are same of a turbogenerator.Although the short circuit current flow when two phase of turbogenerator are shorted(where current can't flow without potential difference),why?
what kelvin's law ?
What is contract demand in solar system?
can anyone please help me to find the rupturing or breaking capacity in KA of circuit breaker (MCCB,VCB,ACB etc) of HT and LT side of a distribution transformer...please help with detailed step by step answer...thank you
how we select ac fuse rating of an power inverter???
could anybody able 2 send me jindal steels previous papers fr electrical steam....pls send 2 my id if possible....sirisha.shaik@gmail.com