hi can you give any body fault level calculation, generator
fault level calculation,transformer fault level calculation
for system fault level with equation? i have 3.3kv
generation voltage three gas gen sets, one is 1.9MW,2nd is
2.5MW,& 3rd is 3.8MW & i have 11 kv generation voltage one
gas gen sets is 3.8MW, we are step up to 22kv by transformer
Answer Posted / deltawye
can you give me the exact details & specification like
impedances,power rating service factor etc. of transformer
and generator before we can answer it ...
Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
xfhnchncv?
Write the current equation in series RLC circuits.
If 100 KAV USP dedicated earth got disconnect / Cut. What will happen at load.
Why the power generated in dams is complex power? Why the generators in dams cannot produce Real power directly (i.e power which has zero reactive part)?
As we use capacitior bank in 3ph ckt for improvement of PF, why not we use capacitor in single phase domestric use, at our house their are many inductive equipments,like fan,mixer,tube choke,air conditioner they also draw PF... by using capacitor can they improve PF. if yes--what are advantage and how to connect a capactor in single ph,and which type of capacitor if no- what are disadvantages.
why we dont prefer ac voltage controller instead dimmerstat [if both have same rating] for conducting experiments in laboratories?
How line capacitance & line inductance varies with increase in height tower.
What is the difference between vector surge relay (78) and Pole slip relay (98G)
Which are resistive loads & which one are inductive loads : Refrigerator, Split air conditioner, ceiling fans, well pump, fluoresecent bulbs, T.V, CRT Monitors, Adsl Routers, C.P.U, Printers, Deep Freezers, Speakers, DVD Players, Microwave oven etc. ? Output Power for these Appliances Would be same like this : P = V * A * P.F Or would be changed ? thanks
How to megger test 11 kV cable and the acceptance IR value
How can we connect additional batteries to three phase ups? What are parameters we have to check when connecting?
Who are the manufactures those manufacturing 3Cx2.5sqmm FRLS cables. I heard about FRLS technology adopted only in wires useful for wirings
When calculation of fault current and fault Kva is to be done,why always we use per unit value and why we consider the base kva?
Please tell me the formulaes while designing a substation for power Calculations in designing a 33 KV Substation?????
(In MEP services) HVAC in AC Plant room what else can we provide if the chiller is not considered?