Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are the difference between C-Curve and D-Curve for
MCB's.

Answer Posted / h.shastri

almost all answer is somewhat correct

the main thing is to selection of proper MCB which matches
with your equipments and instruments

for that i'd like to give you an case study...

let's Assume one Heating Control Action

suppose i am using a 1ph. heater of 1200 Watt (5.2 Amps)
now i am controlling heating action using an SSR or
relay/contactor

now if i will select SSR (relay/contactor)'s rating =6 amps
and i also impliment MCB of 6 Amps.b-curve

then in case of heater failer or implimenting different
rating's heater,

assume that circuit is taking some higher current say, 10
Amps in such my SSR(relay/contactor)will damage due to high
load current which is higher then their rating of 6 Amps

but MCB will not trip instently ( it trips after 5-10 min.
because load current is not more then 12 Amps)

in this case MCB will not protect your instruments.

now if i'll decrease MCB's rating it will starts tripping
on and on.....

if i'll select MCB more then 6 Amps again in this case MCB
will not trip

so that, if i m using b curve 6 Amps MCB then i must select
SSR(relay/contactor)'s rating more then 12 Amps say 15Amps.
then and then problem will be solve.

also if i will use MCB of C or D curve then Again i have to
choose instruments which has atleast 3-5 times higher
rating of MCB.

Is This Answer Correct ?    66 Yes 12 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how we can calculate the efficiency of a diesel generator ?

1758


11 kv input, 66 kv input advantages

1444


please send 5yearje solved papers on my email himmatsinghnathawat@gmail.com

1975


Differentiate between kirchhoff’s first law and kirchhoff’s second law?

1112


What are the main parts of central chiller plant? Explain the function of each stage.

4855


i applied for the ap transco please forward the freqventley asked QA

2061


how a flip flop can be used as a latch?

2049


What is the Surge for 1.1 Phase Induction Motor(For Eg.1Hp) 2.3 Phase Induction Motor(For Eg.1Hp) 3.AirConditioner(For Eg 1Ton) 4.Refrigerator(For Eg 180Ltr or 160kW) 5.Induction Cooker 4. Ceiling Fan

2117


How to synchoronize the generator (with gcb,GT) to grid????? ????? from Grid iam getting power (rated 400kv/20kv) through GT and its goes to UAT.,,ST.,, now my generator(rated 20kv ) ready.,, now iam closing my GCB.,, in GT iam suddenly giving 20kv on that Gt.,, what will happend

2117


What is systematic error?

1418


If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a camp site.?

2274


What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.

2390


what is conductor constant of raccun conductor

2297


What is purpose of reactor?.What is different between line and bus reactor?

1987


Brief me about maintenance planning & sheduling of machine tool.

2182