Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

A 11000/415V distribution transformer is fed 415V upon it's LT
side,Do I get 11000V upon it's Primary side ?

Answer Posted / sivakumar

YES

Is This Answer Correct ?    10 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

give me atleast four differences between circuit and network

2173


how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.

2150


please send me privious exam's queation papers of section engineer(electrical).

2056


i m in need of current rating chart of heavy duty pvc/xlpe, cu/al cables. can somebody provide me? if yes, plz send me at ashish_patel111@yahoo.com

2007


Explain the operation of variable frequency transformer?

1138


use of PIR in ehv breaker

2164


what is the sludge current

2120


in electrical control panel. how can i choose the cable rating. (example - 11kw motor, 18-25A mpcb}

2856


How to calculate main incomer rating of APFC Panel ? Let's say i want to find main incomer for 11kV, 1000kVAR Panel.

1949


What is Long rod insulator and it's applications..? merits over the disc insulator ..?

1916


Why is it prefer to initiate circuit breaker failure by "86" lockout relay not by "94" tripping relay ?!

1797


what is the defination of Cable database? What are the points are considered while preparing cable database? Is there any sample available for cable database?

1894


The Howland current source produces a A Unidirectional floating load current B Bidirectional single-ended load current C Unidirectional single-ended load current D Bidirectional floating load current

2083


Please provided formula for calculate the cable size from step up transformer to M.V panel, run overhead aluminum cables, total load is 5mega watt, total length 900 feet.

1761


Connection diagram for KW meter and  Kva meter

2331