Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is effect of unbalaced load -- say R 15A, Y 25A, B 10A

Answer Posted / ravi teja.a

Resulting flow of neutral current. Generally lighting
system has this type of unbalance. If neutral is not
provided then star point will be shift from its ideal place
to new place with the phase angle related to phase(which
has the higher current value in mentioned phases)caused
over voltage in one or two phase(s).-------is the correct
answer.

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In AC if the direction of current keeps reversing every half cycle, how does it propogate through the transmission lines?

2153


when we design electrical schemes of 11/.415kv distribution..wen and were should we show the relays??what is the function of it?for example..we place EFR Relay CT between transformer neutral link and transformer earth.Like this what are the other type of relays we should use?why?where?Explain please..Thank you

1809


Can we Co-ordinate relay in Load Break switch?

1968


State angle criterion.

1123


in control scheme dc logic wiring commonly using negative loop,what is the reason?if we use positive looping what will happen?

2346


Advantages/Disadvantages of earthing of neutral bus on MSB instead of separate neutral earthing for transformer/DG sets feeding to MSB

2803


thyristor controlled APFC panel design parameter?

1794


How to calculate MCB Breaking capacity.

1527


where are the circulat the diesel in DG parts name with pictue

2143


why tertiary winding is used in transformer with diagram?

2255


What is a compensator?

1094


How shall i select the value of capacitor or inductor in a system?

1906


WHY IN AC DRIVES,INPUT PHASE CURRENT SHOW UNBALANCE?

2303


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING) I O (current operating)?

2216


During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP

1878