Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

is it possible to convert electrical energy to light energy
for transmission purposes?

Answer Posted / x man

can be but the losses will be high

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Name the component u would expect to find in a switchgear assembly?

2025


I had applied for JE in PSEB, Can you pls send me the Question bank for related to my field

1860


for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?

1957


In how we connect watt meter for open & short circuit test of a single phase transformer.

6692


Give two basic speed control scheme of dc shunt motor?

1101


WHAT R THE SAFETIES IN A HIGH TENSION PANEL N LOW TENSION PANEL. ALSO WAT SAFETIES R THERE IN A 200 KVA TRANSFORMER?

2256


Can 33kva/415v transformer be run underground? If the answer is yes why and if the answer is no why?

1574


why wire sizes are 3/29 or 7/29 and why not wire sizes are 2/29 or 6/29?

5142


substation+ plc system

2061


sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.

2220


How I calculate the ELCB for circuit breakers?

2167


Why efficiency in thermal power plant is low?

1105


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1871


I have 1500/1A CT If i connect this CT in 6.6KV bus bar means what will be the voltage present in CT?

1997


How to Make relay co ordination chart for a Electrical power distribution of a plant

3828