Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why only 11kv level is used for transmission purpose? why
not 230v?

Answer Posted / guest

Medium Voltage (11KV) is used for transmittion purpose
cause it reduce the size of cable. V=IR. The cable would be
large if 230V is used for transmittion since current would
be large. Basically, reduce the cost of transmission.

Is This Answer Correct ?    3 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

sir, what is the importance of Fault MVA. how to calculate fault mva of 33kv substation connected by 6.5 km line(single circuit with equal spacing) with 110/11kv transformer in 110kv susbstation.the fault mva on 11 kv bus in 110kv susbstation is 208mva.

2957


Alternator rotor earth fault relay circuit

2078


how can i change the rotation of the AC single phase induction motor and show me by diagram

1807


what is the use of permanent magnet generator in exciter

2167


hai now i am working as a electrical design engineer in construction field can i get a job in oil and gass field or power plant project as a electrical design engineer?

1922


The slip during plugging operation is given by= A 1-s B 2+s C 1+s D 2-s

2844


What are the types of excitation system?

2036


why is the conservator tank painted white on the transformer

3203


What are the no-load losses for the 11000/415V transformer with the following rated capacity? 1.1500 kVA 2. 2000 kVA 3. 2500 kVA 4. 3000 kVA

1757


Generator,motor and alternator Working principal Please explain easily

1474


Is it possible to operate a synchronous 2-poles turbogenerator with a still-in-place faulted bar but electrically disconnected ???? If yes, should I act on the other phases as well ???

1976


How to assume answer to electrical questions

1533


How I calculate the ELCB for circuit breakers?

2182


which protection function should measure RMS value of current&DFT value of current?

2084


what is motor capacity of 80TR chiller? and also say what is the formula related temperature, motor capacity, TR?

2278