How to increase home power factor? Can we connect capacitor
directly? How to select capacity of capacitor?
Answer Posted / thowsif_emerson
U Have to maintain PF 0.9:-
U Can use the Capacitor:-
Input Initial Power Factor
Input Desired Power Factor
Input Load KW (KW)
Log on to
http://www.nepsi.com/kvars_required_calculation.htm
select capacity of capacitor..
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
I HAVE BEEN SELECTED FOR APGENCO A.E(ELECTRICAL) 2008.HOW MUCH WEIGHTAGE FOR INTERVIEW AND WRITTEN TEST.HOW I HAVE TO PREPARE. PLEASE GIVE INFORMATION IF U KNOW.WHAT ABT G.D THIS TIME.CALL RATIO 1:2
Explain and give me an example of a time when you had to explain some new procedures to your co-workers for quality service delivery, how did you go about it?
How to calculate wire length,size & current? ( related to control panel)
Why the standard of ambient teperature mentioned as 40 degree celcius in machines.
is the value of inductance depends upon the evalue of thitha in doubly excited machine?
What is the previous name of Cox's Bazar
For RCD (Residual current device) Icu is defined. How i can find Ics for them?
why do motors burn out? I understand why adding parallel loads to a power source means more current moves through the circuit, and can destroy circuit elements by overheating. What about when you have a vaccuum cleaner intake flush against a floor, a room fan sitting directly against a wall, or a power drill trying to drill through something too hard?
Is vtg is controlled by the resistor? if else how much?
Explain what is electric traction? Explain few advantages of electric traction system?
A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?
Dear Sir/Madam, I have one questions we have three steam turbines and one Gas turbine and our industry linked with the public network, we have protection system one of the protection is reverse power we can export just four MW only i would like to ask about how to calculate the reverse power. Thank you in advance best regards
what r the checklist while installing a 380 kva DG set
What do you mean by Frame 5 Gas Turbine as well as Mark II.
Is it possible to measure correct value of earth resistance & cable insulation ristance with out disconncting earth lead & both sides of cable ends? If not, any other method to measure ER & CIR with out disconneting from the system.