Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we are used D.c. voltage in L.T.side or controling
side.we can use UPS also ,in place d.c. voltage

Answer Posted / mashani

UPS is not DC it's AC....this equipment usually to support
Control system such as Computer Sentral Control....this
equipment is supplied by battery which the battery is DC
source.....and convert by inverter inside UPS to AC source
to supply the emergency equipment...
emergency equipmen is equipment where may not interrupt
even the main source is blackout....
if you mean DC source this could be battery
charger....battery charger ussualy used to operating
controoler....such as PLC, also some electrical equipment
is needed DC source...such as Circuit breaker, ACB(Air
Circuit Breaker) motor inside the breaker is using DC source

Is This Answer Correct ?    0 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

For a stable system, where should the poles of a system be in a root loci plot?

1178


How to Design green buildings services? What is the advantage to design green building?

1747


What Maximam Gap Taibaar & Bush

2263


Single phase and threephase power calculation

2090


What type of wiring series or parallel is used for conventional and addressable type FAS & why?

1760


What is difference between safe PLC and normal PLC

1534


describe the phenomena of vacuum interruption in C.B

1728


Why the standard of ambient teperature mentioned as 40 degree celcius in machines.

1893


i am in need of AC SYNCHRONUS MOTOR 30KW. ANY ONE KNOWS THE MANUFACTURER OF SAME. ALSO MOSFET AC CONVERTER 20KVA CONT.OUTPUT.

1870


how to calculate fault level?

2213


WHY L-G FAULT IS MORE SEVERE IN TERMS OF RRRV?

3137


Why Utility Distribution System in India is mainly at 11 kV? Why not Utility go for 33 kV?

1698


generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...

1877


Is it required to lay 2 runs of GI wires along with armoured cables from one power DB to another Power DB?

1890


Why air circuit breaker off due to power failure?

1140