why we are used D.c. voltage in L.T.side or controling
side.we can use UPS also ,in place d.c. voltage
Answer Posted / mashani
UPS is not DC it's AC....this equipment usually to support
Control system such as Computer Sentral Control....this
equipment is supplied by battery which the battery is DC
source.....and convert by inverter inside UPS to AC source
to supply the emergency equipment...
emergency equipmen is equipment where may not interrupt
even the main source is blackout....
if you mean DC source this could be battery
charger....battery charger ussualy used to operating
controoler....such as PLC, also some electrical equipment
is needed DC source...such as Circuit breaker, ACB(Air
Circuit Breaker) motor inside the breaker is using DC source
| Is This Answer Correct ? | 0 Yes | 4 No |
Post New Answer View All Answers
What is the different between digital phase converter and ordinary phase converter?
How should i design a 1ph & 3 ph transformer. Kindly let meknow all steps and formulaes related to design from scratch.
why we use the 100% and 95% stator earth fault protection for the synchronus generator ?
Can we use a absolute encoder to show rpm of a motor ? what about the condition when power is off ? what is difference if a incremental one is used ?abanirout@gmail.com
I want d.g.set our company
why and how voltage sharing in transformer, during magnetic balance test ?
What does quality factor depend on in resonance?
Which device of PlC does share load between DG sets when DG are running in perallel?
pls tell me function of closing coil of A.C.B.
what is the preventive maintence for ht panels and busbars and vcb abd acb's.
How to measure power in 2 or 4 or n phase circuit? Please give me a formula.
How much load can take a 16 mm aluminum cable 3 phase
What is the distance between body earthing and neutral earthing.?
What is the pro & con of having 11kv & 33kv incoming, and what is the adv & disadv. of converting from 11kv to 33kv.
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?